Our Services

we work with some of the most respected organizations in the country.

addressable fire control panel

the vigilon analogue addressable fire detection manages up to six loops accommodating upto 200 devices on each, including repeat panels, interfaces, call points, sensors, sounders and visual alarams. the vigilon panel is available with 24 and 72 hour standby options. lcd display presents clear indication of fire or fault location and the control panel’s[…]

addressable smoke detectors

advanced detection and communication protocols, easy installation and maintenance, sleek low-profile housing, durable sensor head, no need for replacement, smd circuit board desing high quality and reliability guaranteed. the patented dual angle optical scatter technology allows identification of particle source filtering potential false alaram due to steam and dust. the gas sensing element (CO) within […]

addressabbble heat detectors

the zeos-ad series of analouge addressable detectors have been designed to be fully compatible with the global fire equipment range of intelligent control panel, junior and juno net. compliant to en54-5 and 7 the zeos-ad series detector versions. optionally they can be fitted with a short

Addressable manual call points

mCPE-a is analogue addressable manual call point, designed and manufactured to comply with EN54-11 compatible with all GEF addressable control panel. with its enhanced communication mechanism the typical response time when in alarm is approximately one second depending on the number of call point connected to device loop.

Addressable Fire Alarm Bell&Voice Sounder & Flasher

The Addressable VULCAN 2 DS is available as a detector sounder, Beacon or combined sounder /Beacon. This particular device permits a conventional detector to be connected to the addressable loop via the sounder and/or Beacon. There are also versions available incorporating a loop isolator. All VULCAN 2 DS devices have dip-switch Address setting while tome

Maintenance & Installation of Addressable Fire Alarm System

Installation of addressable systems, programming of addressable systems, Wiring,Conducting, Piping, PVC, Interlink with other systems. Testing & Commissioning, Maintenance, Annual, Semi Annual and Monthly service Contracts.

Conventional Fire Alarm Control Panel

The Xenex conventional Fire Detection and alarm system in Pakistan from GENT by Honeywell provides owners of small building premises with quality protection equipment at an economical price.   BSI approved to EN54: Parts 2 &4, the control panel can be used on installation meeting BS 5839: Control panel Options for 2 to 8 zones can

Conventional Smoke Detectors

Optical Smoke Detectors are ideal at detecting visually smoky fires which are likely to be slow, smouldering fires. ABS casing with red LED fire indicator. The use of the diade base allows monitoring of a removed detector to comply with BS 5839. LPCB approved. N.B. Maximum of 20 per zone.

Conventional Heat Detectors

Heat Detectors respond to changes in temperature and are better suited to smoky, dusty or steamy environment than smoke detectors. We have a comprehensive range of fixed, High temperature and rate of rise devices, making the range suitable for areas where the temperature fluctuates for natural reasons. ABS casing with red LED fire indicator. EN

Conventional Manual Call Points

The GFE-MCPE-C is designed to comply with EN54-11 compatible with all GFE conventional control panels. A bi-colour LED flashes Green when the unit is connected to a control panel and is illuminated Red when in Alarm. MCP from GENT are all with a 470- Ohm resistor and Normally open contact, complete with glass. Weather proof

Fire Alarm Bell & Voice Sounder & Flasher

GENT electronic bell for a wide range of uses. Metal casing available in Red or Grey finish. Suitable for semi flush or surface mounting. VULCAN 2 VOX C is a wall mounted Conventional voice Sounder which is available in either White or Red housings. Multi-Message, Follow Panel`s Sounder Programming. Multi-Language, 92dBA maximum output. Message easily […]

Maintenance & Installation of Conventional Fire Alarm System

Maintenance & Installation of Conventional Fire Alarm System Installation of Conventional systems, Wiring, Conducting, Piping, PVC, Interlink with other systems. Testing & Commissioning, Maintenance, Annual, Semi Annual and Monthly service Contracts. (….)

Fire Hydrant System

Fire hydrant system is the standalone fire fighter in any establishment. A Hydrant system is basically water distribution network backed by a number of components & accessories like Fire Booster Pumps, Jockey Pumps, Diesel Engines, Fire Hose Reels, Hose Pipe, Fire Hose Cabinet, Hydrant Valve, Gate Valve, Alarm Check valve, Foot Valve, Ball Valve, Stand(….)

Breeching Inlets

Providing and fixing breeching inlets 2-way (manufactured & comply to BS-5041-3-1975) , NAFFCO Model NBC-096 or Bristol UK, SRI Malaysia, SAFFECO Global etc..(….)

Wet Type Pillar Fire Hydrant

Wet Type Pillar Fire Hydrant Providing and fixing of External 4″ dia Flanged, Wet type fire hydrant pedestal type with controllable outlet and body of gray cast iron to BS 1503 while outlet is Copper Alloy to BS 12163 with Test Pressure of 24 Bars NAFFCO Model NHYD-060, Bristol, LIFECO UAE, SAFFECO Global etc(….)